9
Technical Specifications
DESCRIPTION
POWER PLUS
50 M 100 M 100 S 100 M DEP 100 S DEP
Fuel G20 - G30 - G31
Appliance category II2H3+
Type of appliance B23 - C63 - C63x
Heat input ref. HHV (min - max) G20 16,3 - 50 16,3 - 100 16,3 - 100 16,3 - 77,3 16,3 - 77,3 kW
Heat input ref. NHV (min - max) G20 15 - 45 15 - 90 15 - 90 15 - 69,6 15 - 69,6 kW
Useful heat output (80°/60°C) (min - max) 14,8 - 44,2
14,8 - 88,3 14,8 - 88,3
14,8 - 68,5 14,8 - 68,5 kW
Useful heat output (50°/30°C) (min - max) 16,3 - 48,5 16,3 - 96,8 16,3 - 96,8 16,3 - 75,3 16,3 - 75,3 kW
Useful effi ciency ref. NHV (80°C/60°C) 98,2 98,2 98,2 98,4 98,4 %
Useful effi ciency ref. NHV (50°C/30°C) 107,7 107,7 107,7 108,2 108,2 %
Useful effi ciency at 30% ref. NHV
(80°C/60°C)
98,7 %
Useful effi ciency at 30% ref. NHV
(50°C/30°C)
108,7 %
Losses through the chimney with the burner
operating
1,3 %
Losses through the chimney with the burner off
0,1 %
Losses through the casing (Tm=70°C) 0,5 %
Flue gas temperature Return temp. + 5 °C
CO
2 at minimum - maximum G20 9,0 - 9,0 %
CO
2 at minimum - maximum G30 - G31 10,4 - 10,4 %
CO without air at minimum - maximum less than
11 - 91 mg/kWh
NOx class 5
Maximum operating pressure, central heating
6 bar
Maximum admissible temperature 90 °C
Range of boiler water temperature settings
(± 3 °C)
20 - 80 °C
Water content 5 10 10 10 10 l
Power supply 230 - 50 V-Hz
Maximum power input 169 333 333 333 333 W
Index of protection X0D IP
Quantity of condensate 7,2 14,4 14,4 11,2 11,2 kg/h