BestCode Next Series 8 Technical Manual October 2022 Page 98 of 290
Fluidic Service Routines
SmartFill Cup removal
Be familiar with proper safety information for handling fluids.
Procedure Time: 5 minutes
1. Remove the SmartFill Cap and 3
screws that secure the SmartFill Cup
Assembly to the Controller.
2. Lift the tube out of the tank.
Spray Cleaner on the black
gasket to help ease
removal and installation of
the tube.
3. Locate and disconnect the SmartFill
Cup Assembly antenna coax cables.
Color Codes:
Black = Ink SmartFill Cup Assembly
Blue = SmartFilter Reader Assembly
White = Makeup SmartFill Cup Assembly