BestCode Next Series 8 Technical Manual October 2022 Page 290 of 290
Maintaining the Factory Air Dryer
Under normal operation, the Air Dryer has only 1 service item required, 46-0005-01 Filter, Air Dry Kit.
Information on filter life can be found here.
Installation control requirements:
Air pressure should be 75PSI @ 2.5CFM
For use in environments 0-45C.
Air temperature should not exceed 100F
o May require inline air-chiller or oil separator (not provided by BestCode)
Special Notes:
a. System will automatically shut off jet if electronic control temperature exceeds 60C.
b. If air pressure drops below 40 PSI the Pressure sensor will state change and the system will
automatically power off.
c. 44-5051-01: Factory Air Dryer-Enclosure/Printhead Pressurization kit is not intended for use where
oil in present in the lines. Oil cannot be properly purged by the dryer and builds up in the Micro-mist
separator and Membrane filters. This is particularly relevant in food processing applications that use
food grade lubricant in their air compressor. The oil will build up in Micro-mist separator and
Membrane Filter, preventing air flow into the cabinet, causing cooling fault for the printer due to
low pressure at the pressure transducer.
Appendix Y Companion Documents
Version 01.05.02.05 makes use of 1 companion document.
Bestcode Remote Comm 2.4.docx
Determining Gen 1 and Gen 2 Fluidic Systems
Safety Data Sheets: https://support.bestcode.co/safety-data-sheets/