BestCode Next Series 8 Technical Manual October 2022 Page 179 of 290
Prompt Code
Prompt Name
Prompt Description
11-000A
-
"Makeup level has risen to Good."
Sent to the remote user to indicate that the makeup level, as measured by the Level Switch, has risen
to "good."
Prompt Code
Prompt Name
Prompt Description
11-000B
-
"Makeup level has risen to Full."
Sent to the remote user to indicate that the makeup level, as measured by the Level Switch, has risen
to "full."
Prompt Code
Prompt Name
Prompt Description
11-8001
Makeup Fault
SmartFill label not valid for this machine.
Solution 1:
Label type cannot be used in the BestCode machine. Contact BestCode.
Prompt Code
Prompt Name
Prompt Description
11-8002
Makeup Fault
SmartFill label not valid for this machine setting.
Solution 1:
The wrong fluid is being installed. Do not add this bottle. Check the Info screen for the commission ink
type and add the correct fluid.
Prompt Code
Prompt Name
Prompt Description
11-8003
Makeup Fault
Makeup fluid level could not be determined.
Solution 1:
Makeup float switch is not plugged in. Check connection on J28.
Solution 2:
Makeup float switch is not operating correctly. Replace the Makeup Float Switch.
Prompt Code
Prompt Name
Prompt Description
11-8004
Makeup High
Makeup fluid level too high to operate.
Solution 1:
Makeup float switch is not operating correctly. Inspect the fluid level in the makeup tank. If fluid level
is OK, replace the Makeup float switch.
Solution 2:
Makeup tank is over-filled. Drain the makeup from the tank and install fresh makeup.
Prompt Code
Prompt Name
Prompt Description
11-8005
Makeup Fault
SmartFill makeup label required.
Solution 1:
Scan SmartFill makeup label. Do not add makeup Bottle. Occurs when fluid is added but SmartFill label
is not read. Review Makeup Add Instructions..
Prompt Code
Prompt Name
Prompt Description
11-8006
Makeup Fault
SmartFill makeup label required.
Solution 1:
Scan SmartFill makeup label. Do not add makeup Bottle. Occurs when fluid is added but SmartFill label
is not read. . Review Makeup Add Instructions..
Prompt Code
Prompt Name
Prompt Description
11-8007
Not Used
-
Solution 1:
Load new Firmware.
Prompt Code
Prompt Name
Prompt Description
11-8008
Not Used
-
Solution 1:
Load new Firmware.