Description of the activity Frequency Type of action
Tightening the electrical terminals yearly tightening with tool
Tightening ground anchoring nuts yearly tightening with tool
Cleaning the front monthly washing with water
Cleaning the fan lter monthly blowing with compressed air
Cleaning the Retractor (only for exit sta-
tion)
monthly blowing with compressed air and
electrostatic cloth
Cleaning the printer (only for entry station) every 8000 tick-
ets or every six
months
blowing with compressed air and
electrostatic cloth
Checking the fan operation monthly visual check
Checking the anti-condensation resistor
operation
every six
months
check with contact and temperature
sensor
Detector loop sensor reset monthly reset button pressure
Check of the ticket quality if the station
has been inactive for some time
monthly visual and contact check
16.1 - MAINTENANCE SCHEDULE