3.5 Aligning the turbine
The turbine is installed with an
adjustment bracket in a hanging
position.
Attach the adjustment bracket with
the turbine to the stay bolts.
The top nuts determine the
positioning and also the flow of
the turbine.
The factory setting for the
discharge angle is approx. 4°. In
most cases, the angle does not
have to be changed.
Based on pool size, depth, and
user requirements, the angle can
be adjusted by means of stay bolts.
Then, adjust the height of the
turbine.
Tighten and lock all nuts
securely.
The flow plate with the flow aid can
only be installed when the turbine
is correctly aligned.
3.6 Installation of the cover plate
Align the turbine and do a trial run
Do not install the cover plate (3) until the turbine is correctly aligned.
There is a flow aid attached to the inside of the cover plate.
The cover plate cannot be installed until the turbine is correctly aligned and protrudes into the flow
aid.
Place the cover plate on the press frame (2) and fix it with the countersunk head screws M5, while
supporting the cover plate with one hand or slightly lifting it to prevent damage to the countersunk
head screws.
Observe the specified tightening torque (4 - 6 Nm)!