11. Specifications
Supply voltage: 1×230 V +6/-10%, 50 Hz
Motor protection: No external motor protection is necessary
Degree of protection: IP 44
Winding class: insulation class H
Ambient temperature: max. 40 °C
Max. system pressure: 10/16 bar
Noise sound pressure level under 55 dB(A)
Leakage current: The pump’s power line filter causes a leakage current
to the ground wire of less than 3.5 mA during operation.
11.1 Technical data: Standard design
Media temperature: +15 °C bis 95 °C
Media temperature: +15 °C to 95 °C
If a build-up of condensation water appears
(media temperature lower than ambient temperature)
the recessed design must be used.
Ambient temperature: max. 40 °C
Ambient temperature Media temperature
°C Min. °C Max. °C
15 15 95
20 20 95
25 25 95
30 30 95
35 35 90
max. 40 40 70
12. Disposal
This product and its parts must be disposed of ecologically.
11.2 Technical data: Recessed design
Media temperature: Media temperature: +15 °C to 110 °C
If a build-up of condensation water appears
(media temperature lower than ambient temperature)
we recommend the cold water design with condensation-resistant paint.
Ambient temperature: max. 40 °C
80