Saving And Recalling Settings
The electronic load has internal registers in which settings (mode, current, voltage,
resistance, transient level, etc.).Users could use
Shift
+
Store
and
Shift
+
Recall
to save and recall the relative data as following:
CC value /CW value /CR value /CV value
Transition current A value /Transition current B value /Transition voltage A value
/Transition voltage B value / Transition power A value /Transition power B value
/Transition Resistance A value /Transition Resistance B value
Current A pulse width time/ Current B pulse width time/Voltage A pulse width time/
Voltage B pulse width time /Power A pulse width time/Power B pulse width time
/Resistance A pulse width time /Resistance B width time
Transition current testing mode/Transition voltage testing mode/Transition power
testing mode /Transition resistance testing mode
Max current value / Max voltage value / Max power value
Battery Testing
Load provides the function of discharging electronic of testing battery. Setting
discharging current by press
I-set
, then press
Shift
+
Battery
to set the mix
voltage, Battery testing operation is run. When Battery Voltage setting value is lower
than the limited voltage; Load will turn off the input. VFD will display the capacity of
testing battery, Press
Shift
+
Battery
and return the normal mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision 8500 Series and is the answer not in the manual?

BK Precision 8500 Series Specifications

General IconGeneral
Series8500
Voltage Range0-120V
DisplayLCD
InterfaceUSB, RS232, GPIB (optional)
ModesCC, CV, CR
CategoryElectronic Load

Related product manuals