STATus:OPERation:INSTrument:CONDition?
This command queries parameters from operation condition sub register. After this command is executed,
the operation condition sub register is reset.
Note: this command is only valid for current channel.
Command syntax: STATus:OPERation:INSTrument:CONDition?
Return parameter: <parameter of operation condition register>
Example: STAT:OPER:INST:COND?
INSTrument[SELect]
This command can be used to select the channel.
Command syntax: INSTrument[:SELect]
Parameter: FIRst|SECOnd|THIrd
Reset value: FIRst
Example: INST SECO
INSTrument[:SELect]?
This command returns the number of the selected channel
Command syntax: INSTrument[:SELect]?
Return parameter: FIRst|SECOnd|THIrd
Example: INST?
INSTrument:NSELect
This command is similar to the command “INSTrument[SELect]”, the only difference is that this command
uses numbers to denote the channel.
Command syntax: INSTrument:NSELect
Parameter: 1~3
Reset value: 1
Example: INST:NSEL
OUTPut[:STATe]
This command sets the output state for the current channel to ON or OFF
Command syntax: OUTPut[:STATe] <parameter>
Parameter: 1(ON)|0(OFF)
Example: OUTP 1
OUTPut[:STATe]?
This command queries the output state of the current channel is ON or OFF
Command syntax: OUTPut[:STATe]?
Return parameter: 0|1
Example: OUTP?
OUTPut:TIMer:DATA
This command sets the time of the output-timer for the current channel.
Command syntax: OUTPut:TIMer:DATA <parameter>