Parameter: 0~999999S (if you set 0S,the output-timer will be disabled.)
Reset value: It is concerned about the parameter you set in the menu.
Example: OUTPut:TIMer:DATA 100
OUTPut:TIMer:DATA?
This command queries the time of the output-timer for the current channel.
Command syntax: OUTPut:TIMer:DATA?
Return parameter: 0~999999
Unit: S
Example: OUTP:TIM:DATA?
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
This command sets the current value of the power supply.
Command syntax: [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <parameter>
Parameter: MIN|MAX|MIN TO MAX
Unit: A mA uA
Reset value: It is concerned about the parameter you set in the menu.
*RST value: MAX
Example: CURR 2A
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
This command checks the current value of the power supply.
Command syntax: [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? <parameter>
Parameter: MIN | MAX |None
Return parameter: MIN TO MAX
Unit: A
Example: CURR?
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
This command sets the voltage value of the power supply.
Command syntax: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
Parameter: MIN|MAX|MIN TO MAX
Parameter: V mV uV kV
Reset value: IN TO MAX|MIN|MAX
*RST value: MIN
Example: VOLT 10V
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]?
This command reads the voltage value of the power supply.
Command syntax: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? <parameter>
Parameter: MIN|MAX|None
Reset value: MIN TO MAX
Unit: V
Example: VOLT?