OM6003.PUB Page 25 DATE PRINTED: 4/7/11
© Blaze King Industries Canada Ltd June 2006 Version 1.07SIT
The Contemporary by Blaze King Owners Installation and Operation Manual
INSTALLER: Before leaving the appliance with the customer, you must check the operation of the appliance:
Check correct BTU rating by clocking the appliance at 15 minutes (see certification label).
Check flame picture. Adjust primary air if required (see page 19).
Take time to go through the operation of this unit with the customer.
NOTE: When first fired, the unit will produce an odor. This is normal and is part of the paint
curing process, it may be noticeable for at least 4 hours. It is recommended that you open a few
windows to ventilate the room. During the first hour smoke detectors in the house may be set off.
Following the initial burn-in period, the glass panel may require cleaning.
CAUTION: Do not clean the glass when the appliance is hot!
When the appliance is cold, firing may cause the glass to fog up. This is due to condensation and
is normal.
Make yourself familiar with these instruction before operating the appliance.
Check any loose electrical wires that may cause a shock.
Check around the appliance for gas leaks. IF YOU SMELL GAS, follow the instructions on the
front cover of this manual.
Check to see that logs are correctly positioned. The pilot light should be visible.
Check to make sure that venting is secure.
Check all external parts, such as grills, doors and control cover are properly attached and
fastened.
CAUTION: Do not turn the unit off and on again without a minimum of a 60 second wait
between firing.
Make sure you read this entire manual, especially the lighting instructions on page 5, before
you begin stove operation.
Keep in mind that your thermostat will only work to control your stove if the ON/
OFF rocker switch is set to the “OFF” position. The “ON” position will prevent
the thermostat from controlling the stove. When you are lighting your pilot your
thermostat should be set to the lowest level and the ON/OFF rocker switch
should be set to “OFF”.
Operating Instructions
Press and turn the knob clockwise to the OFF position.
To turn off the main burner only, set the thermostat to the lowest setting or turn remote switch to OFF. Press
and turn the knob clockwise to PILOT position.
TEMPORARY SHUT-DOWN
CONTROL KNOB POSITIONS
Pilot
SIT
Robertshaw
Burner OnUnit Off
FINAL CHECK
ON/OFF
rocker switch
COMPLETE SHUT-DOWN
SIT
Robertshaw
SIT
Robertshaw