PAGE 7
OM-8003 & 8004
Date Printed: Tuesday, February 08, 2005
Revision Date: 06-12-03
COPY OF APPROVAL LABEL
This appliance must be install in accordance with the manufactures instructions.
This appliance must be installed in accordance with local codes if any; if not follow the current ANSI Z223.1 or
CAN/CGA-B149
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to Sidewall 11 in. (280mm) Alcove Minimum Width 47” (1194mm)
Unit to Backwall 6 in. (152mm) Alcove Minimum Height 54” (1372mm)
Unit to Adjacent Wall Corner 4 in. (102mm) Alcove Maximum Depth 30” (762mm)
Unit Top to Mantel 18 in. (457mm)
18” Floor Protection required if unit is not on a 6” or higher elevated Hearth (8003 only)
Electrical Rating: 115 Volts, 0.7 Amperes, 60HZ.
DANGER: Risk of electrical shock. Disconnect power before servicing unit. Do Not route power cord beneath
heater. Not for use with Solid Fuel.
Manufactured by: Manufacture Date:
Blaze King Industries Valley Comfort Systems
146A St. 1290 Commercial Way
Walla Walla, WA. Penticton, B.C
99362 USA V2A 3H5 Canada
Tested to ANSI Z21.88-1998*CSA 2.33-M98 “Vented Gas Fireplace Heaters” and CAN/CGA
2.17-M89 “ High Altitude” This vented gas fireplace is not for use with air filters.
JAN FEB MAR APR
MAY JUN JUL AUG
SEP OCT NOV DEC
2003 2004 2005 2006
WH-
BLAZE KING PEGASUS 8003 & 8004
Vented Gas Fireplace Heater
Not For Use With Solid Fuel
Not for installation in a Mobile Home
This stove is factory equipped for: Natural Gas Propane
Certified for U.S. and Canada
Homologue Pour Le Canada
Insert model 8003 NATURAL GAS L P GAS
Freestanding model 8004
Freestanding / Insert Freestanding / Insert
Input Rating (BTU/hr) 0-610m (0-2000 ft.) Alt. 38,000 38,000
Orifice Size (DMS) 0-610m (0-2000 ft.) Alt. 31 50
Input Rating (BTU/hr) 610-1370m (2000-4500 ft.) Alt. 35,100 (Can. Only) 35,800 (Can. Only)
Orifice Size (DMS) 610-1370m (2000-4500 ft.) Alt. 32 51
Unit Comes Factory Equipped For 0-610m (0-2000 ft.) Alt.
Minimum Input (BTU/hr) 20,500 19,000
Manifold Pressure (in w.c. / kPa) 3.5 / 0.87 11.0 / 2.74
Manifold Pressure - Low Setting (in w.c. / kPa) 1.3 / 0.32 2.7 / 0.67
Minimum Inlet Pressure (in w.c. / kPa) 4.5 / 1.12 12.2 / 3.04
Maximum Output with Fan On (BUT/hr) 29,800 29,600