PAGE 9
OM-8003 & 8004
Date Printed: Tuesday, February 08, 2005
Revision Date: 06-12-03
ELECTRICAL GROUNDING INSTRUCTIONS
PLANNING YOUR STOVE PLACEMENT
As you plan your installation, consider the following:
The stove should be placed in the home in a position that is as central as possible. Consider safety, convenience, traffic flow, and the fact
that the stove will need a venting system. Pay special attention to prevailing winds when choosing termination location.
DUE TO HIGH TEMPERATURES, THE ROOM HEATER SHOULD BE LOCATED OUT OF TRAFFIC AREAS AND AWAY FROM
FURNITURE OR DRAPERIES. MINIMUM CLEARANCES SHOWN ON PAGE 14 ARE TO PREVENT WALLS AND CEILINGS FROM
CATCHING ON FIRE.
For the type of vent system to be used, see page 15. Electrical Power is 115-60 HZ. The stove is equipped with a fan assembly with a six
foot electrical cord. Do not route the cord in front of the stove. Position the stove in its final location. A floor protector may be used for
aesthetics, however, the freestanding 8004 units may be installed directly onto carpet, vinyl, or any other flooring.
WARNING
ONLY PERSONS LICENSED TO WORK WITH GAS PIPING MAY MAKE THE NECESSARY GAS CONNECTION TO THIS
APPLIANCE. YOU ARE NOW READY TO HOOK UP THE GAS SUPPLY. BE SURE GAS PLUMBING INSTRUCTIONS AND ALL
PROVINCIAL AND LOCAL CODES ARE CAREFULLY FOLLOWED. USE APPROVED FLEXIBLE GAS CONNECTIONS OR RIGID
PIPING DEPENDING ON PROVINCIAL AND LOCAL CODES TO ATTACH BURNER TO GAS SUPPLY. BE SURE TO USE PROPER
SIZE GAS SUPPLY LINE. CAREFULLY CHECK ALL CONNECTIONS FOR GAS LEAKS WITH SOAP AND WATER SOLUTION.
EACH INSTALLATION MUST CONFORM TO ALL LOCAL, PROVINCIAL AND NATIONAL CODES. REFER TO THE NATIONAL FUEL
GAS CODE AND LOCAL ZONING AND CODE AUTHORITIES FOR DETAILS ON INSTALLATION REQUIREMENTS. BLAZE KING
APPLIANCES MUST BE VENTED TO THE OUTSIDE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL FUEL GAS
CODE. IN THE ABSENCE OF LOCAL CODES, THE INSTALLATION MUST CONFORM WITH CURRENT EDITION OF THE
NATIONAL FUEL GAS CODE ANSI Z223.1, ALSO KNOWN AS NFPA 54, OR CAN 1-B149.
WARNING: The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes
with the current National Electrical Code ANSI/NFPA 70, or the current Canadian Electrical Code CSA.C22.1.
This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into
a properly grounded three prong receptacle.
DO NOT cut or remove the ground prong from this plug.