Date Printed: Tuesday, February 08, 2005
Revision Date: 06-12-03
HIGH ALTITUDE STATEMENT
This unit has been tested for installations at a high altitude up to 1370 meters (4500 ft.) in
accordance with Canadian test standard CAN/CGA-2.17. Higher altitudes effect atmospheric
pressure and heat value of gaseous fuels. When installing this unit at high altitudes, the rated
input will be lower than at sea level. The lowered oxygen content in the air and lowered gas
density requires installing a different orifice in order to achieve clean combustion of the unit.
Consult the unit data plate for proper high altitude orifice size, and fill out the information sticker
attached to the unit when field converting. For high altitude installations, consult the local gas
distributor or the authority having jurisdiction for proper rating methods.
BURNER CONVERSION
The conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authorities having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury
or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is
not proper and complete until the
operation of the converted appliance is
checked as specified in the owner
instructions supplied with the kit.
Cet èquipement de conversion sera
installè par une agence qualifièe de
service conformèment aux instructions du
fabricant et toutes exigences et codes
applicables de l`autorizès avoir la
juridiction. Si l`information dans cette
Instruction n`est pas suivie exactement,
un feu, explosion ou production de
protoxyde de carbone peut rèsulter le
dommages causer de propiètè, perte ou
blessure personnelle de vie. L`agence
qualifièe de service est esponsable de
l`installation propre de cet èquipement.
L`installation n`est pas propre et complète
jusqu`à l`opèration del`appareil converti
est chèque suivant les critères ètablis
dans les instructions de propriètaire
provisionnèes avec l`èquipement.
USE ONLY CONVERSION KITS LISTED BELOW
(Models 8003 & 8004) Robertshaw Kits
BLAZE KING PART#’s:
NATURAL GAS- Z0747A (0-2000ft. # 31 main orifice) &
Z0749 (2,000-4500ft.# 32 main
orifice)
PROPANE GAS- Z0736 (0-2000ft/#50 main orifice) &
Z0736H (2,000-4500ft.#51 main
orifice)
USE ONLY CONVERSION KITS LISTED BELOW
(Models 8003 & 8004) Honeywell Valve & Pilot
BLAZE KING PART#’s:
NATURAL GAS- Z0751 (0-2000ft. #31 main orifice) &
Z0751B (2,000-4500ft.# 32 main orifice)
PROPANE GAS- Z0769 (0-2000ft/#50 main orifice) &
Z0769H (2,000-4500ft.#51 main orifice)