Changing Settings on the SuperUser Display
Reheat Pulse Interval
You use the Reheat pulse interval setting to specify the interval in seconds between
injec-tions of water during the regeneration process. The injection itself lasts 1/10 of
a second. The default setting is 8 seconds.
1. On the SuperUser display, touch Adjustments, and then touch Reheat
pulse interval.
2. Drag your finger up or down to select from 4s to 24s in intervals of 2 and
then touch OK.
Proving Pulse Interval
You use the Proving pulse interval setting to specify the interval in seconds between
injec-tions of water during the proving process. The injection itself lasts 1/10 of a
second. The default setting is 20 seconds.
1. On the SuperUser display, touch Adjustments, and then touch Proving
pulse interval.
2. Drag your finger up or down to select from 12s to 44s in intervals of 4,
and then touch OK.
Proving Pulse Length
You use the Proving pulse interval setting to specify for how long each injection of
water lasts during the proving process. The default setting is 1 second.
1. On the SuperUser display, touch Adjustments, and then touch Proving
pulse length.
2. Drag your finger up or down to select the preferred length: 0.6, 1.0 or
2.0 seconds, and then touch OK.
16 SERVICE MANUAL