Troubleshooting
Error Code 10
The temperature sensor (probe) in the drain is broken. The oven can still
be used, but the error has to be corrected as soon as possible.
Steps
Check list
Solution
1 Go to the test menu (oven) to see
which temperature is displayed.
2 Check the cable and the cable plugs
and change the plug if necessary.
3
Test the sensor using an ohmmeter,
If no, change the probe.
and check whether the value matches
the value in the table and the current
temperature.
4
Check each lead to ground for shorts
Error Code 11
There’s not enough water. The steam generator was not filled to high level
water within 2 minutes.
Steps
Check list
Solution
1 Go to the test menu (steam generator)
to see if the water level is correct. Check
water level in front of sensor. Check that
water is turned on. The water pressure
should be at least 30psi
2
Test whether the solenoid valve and
Clean the solenoid valve.
the level sensor are working (is 24VAC
measured at the coil when the fill valve is
activated?)
3
Check water level tube for debris.
Water could be too pure to sense.
38 SERVICE MANUAL

Other manuals for Blodgett BCT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blodgett BCT Series and is the answer not in the manual?

Blodgett BCT Series Specifications

General IconGeneral
BrandBlodgett
ModelBCT Series
CategoryOven
LanguageEnglish

Related product manuals