Troubleshooting
Error Code 8
The probe is broken or is not connected properly. The program cannot be
used until the error has been corrected.
Steps
Check list
Solution
1 Go to the test menu (miscellaneous)
to see which information is displayed.
2 Check the cable and the cable plugs
and change the plug if necessary.
3
Test the sensor using an ohmmeter,
If no, change the probe.
and check whether the value matches
the value in the table and the current
temperature.
Error Code 9
The temperature sensor (probe) in the boiler is not working properly. Programs
using the steam cannot be used until the error has been corrected.
Steps
Check list
Solution
1 Go to the test menu (steam generator)
to see which information is displayed.
2 Check the cable and the cable plugs
and change the plug if necessary.
3
Test the sensor using an ohmmeter,
If no, change the probe.
and check whether the value matches
the value in the table and the current
temperature.
4
Check each lead to ground for shorts
SERVICE MANUAL 37

Other manuals for Blodgett BCT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blodgett BCT Series and is the answer not in the manual?

Blodgett BCT Series Specifications

General IconGeneral
BrandBlodgett
ModelBCT Series
CategoryOven
LanguageEnglish

Related product manuals