EasyManua.ls Logo

Bluetti EP800 - Commissioning and Decommissioning

Bluetti EP800
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JUST POWER ON62
7.2 Commissioning
Step 1: Switch on the DC power on EP800.
Step 2: Switch on the DC circuit breakers on B500 battery packs. Press and hold the
power button on any B500 for 3 seconds, the button lights up green.
Step 3: Wait for about 40 seconds till the inverter indicator keeps steady green.
Step 4: Switch on the AC circuit breakers and rapid shut down switch connected to
the inverter GRID terminal.
Step 5: Turn on “System Switch” in the BLUETTI App. For details, please refer to
BLUETTI App User Manual.
Step 6: Check the output voltage of BACKUP terminal.
Step 7: Switch on the AC circuit breakers connected to the inverter BACKUP
terminal.
Step 8: Check the EP800 system status through the App.
7.3 Decommissioning
Step 1: Turn off the “System Switch” on BLUETTI App.
Step 2: Switch off the AC circuit breakers connected to the inverter GRID and
BACKUP terminals.
Step 3: Switch off the DC power of the inverter.
Step 4: Press the circular power button on any B500, the button light flashes green.
Step 5: The indicator continues to flash.
Step 6: When the indicator is off, B500 battery packs turn off.
Step 7: Switch off main switches for all B500 and the EP800 powers off.
Warning
There is still residual voltage after the EP800 is powered off, which
may cause electric shock or burns. Please wait at least 30 minutes
before operating the system.