Usage Problems
Fault Reason and Solutions
1. Motor running and
suddenly stops
Obstacle sensitivity may be set too low
and as the motor starts running its
current value is higher than the
obstacle sensitivity, this will cause the
motor to stop.
Solution: Adjust the sensitivity value
2. Auto travel learning fail 1. When the motor is in its auto
travel learning process and the
infrared / remote / terminal signal
triggers learning fail
Solution: Don’t trigger infrared / remote/
terminal signal when the motor is in
auto travel learning
2. Auto travel learning time is to short
Solution: The control boards single
direction work time request must be
more than 5s, if it’s not then auto
travel learning will fail
Attaching Control Box Lid
CONTROL BOX
SCREW
WASHER
Install the screw and washer
to secure the lid of the box