Gate Stop must be installed in the centre of the driveway for double gates to
close up onto and apply solid pressure.
Arm Condensation Drain Hole: Always mount arms with condensation drain
holes facing down or water will enter the motor and damage the electrics
voiding the warranty.
This is indicated on your arm with the “THIS SIDE DOWN” marking.
Actuator Arms must not be parallel with the gate but must be level with the
gate.
Wiring Double Gates:
Connect your arms to [MOTOR1] and [MOTOR2(MAIN)].
We recommend using .66mm wire or greater. Lighter cable will restrict the
performance of the system. Use a suitable electrical junction box to protect
cable joints from moisture damage.
Please note:
Motor forward and reverse judgement: when the motor is running, the LED
display should show OP, the gate must be in its opening state, when the LED
display shows CL, the gate must be in its closing state.
Only when the motor power cable is correctly connected, the system can
function normally.
Safety Feature
Rebound function: If the gate is encountering resistance in high speed running
period, the gate will stop and then rebound.
Limit function: If the gate is encountering resistance in the end position, the
motor will automatically stop running to achieve the limit.
Stall force can be adjusted through P1 to P4.
Other Considerations