Troubleshooting 6.3 List / Meaning of Message Codes
Page 32 BOGE base control for scroll compressors
6.3 List / Meaning of Message Codes
The table below is used to narrow down the causes of messages so that po-
tential faults and problems during compressor operation can be prevented or
rectified quickly.
It contains a list of message codes that may be issued by the base control.
Each message code has a specific cause. The causes of the messages are
specified in the table next to the codes, along with possible corrective mea-
sures.
If in doubt, BOGE recommends contacting BOGE Product Support in the
event of warnings, maintenance messages or faults.
You can contact BOGE Product Support on:
Telephone: +49-520-660-1140
Type Code Message / Cause Corrective Measures
First
then
1 Final compression temperature Lower ambient temperature by venting.
2 Motor overtemperature
Have the motor and pressure generation of the compressor
checked by BOGE Service personnel.
10 Motor servicing due Have the component serviced by BOGE Service personnel. *
11 Compressor servicing due Have the component serviced by BOGE Service personnel. *
14 (Intake) temperature too low Increase ambient temperature at the installation site.
15 Suction regulation
Have the suction regulator checked and if necessary replaced
by authorized, qualified personnel or BOGE Service person-
nel.
16 Network pressure sensor
Have the network pressure sensor replaced by BOGE Service
personnel.
18 Fault on an external control
Have the control settings in the master / slave parametri-
zation checked and if necessary corrected by authorized,
qualified personnel.
Have the master control checked for proper functioning
and if necessary replaced by BOGE Service personnel.
Have the cabling between the controls checked by an
authorized, qualified electrician.
19 Power failures too frequent
Too many motor switching cycles caused by interruptions
in the electrical supply. If necessary, have the compres-
sor checked by BOGE Service personnel.
Have the power supply checked by an authorized, quali-
fied electrician.