ā¢
3.3 Operating characteristics
Parameter Local Remote 412 defines the operating characteristics and enables choosing control via
contacts/control unit and/or the interface.
412
Local Remote
- Selection
44 - Ctrl. Cont.+KP,
Dir. Cont.+KP
Operation Modes of Parameter 412
0 - Control via Contacts
Commands Start and Stop as well as definition of
sense of rotation via digital signals.
1 - Control via Statemachine
Commands Start and Stop as well as definition of
sense of rotation via DRIVECOM statemachine of
2 - Control via Remote-Contacts
Commands Start and Stop as well as definition of
sense of rotation via logic signals through the commu-
3 - Ctrl. KP, direction Contacts
Commands Start and Stop from the control unit, defi-
nition of sense of rotation via digital signals.
4 - Ctrl. KP+Cont., direction Cont.
Commands Start and Stop from the control unit or via
digital signals, definition of sense of rotation only via
5 - Ctrl. 3-Wire, direction Cont.
3-wire; control of sense of rotation and the signal
Start 3-wire ctrl. 87 via digital signals.
13
- Control via KP, Direction KP
Commands Start and Stop as well as definition of
sense of rotation via control unit.
14
- Control KP+Cont., Direction KP
Commands Start and Stop via the control unit or digi-
tal signals, definition of sense of rotation only via con-
20
- Control Contacts, Clockw.
Commands Start and Stop via digital signals. Fixed
definition of sense of rotation: clockwise only.
23
- Control Keypad, Clockw.
Commands Start and Stop via control unit. Fixed defi-
nition of sense of rotation: clockwise only.
24
- Control Cont. + KP, Clockw.
Commands Start and Stop via control unit or digital
signals. Fixed definition of sense of rotation: clockwise
30
- Control Contacts, Anticl.
Commands Start and Stop via digital signals. Fixed
definition of sense of rotation, anticlockwise rotation
33
- Control Keypad, Anticl.
Commands Start and Stop via control unit. Fixed defi-
nition of sense of rotation, anticlockwise rotation only.
34
- Control Cont. + KP, Anticl.
Commands Start and Stop via control unit or digital
signals. Fixed definition of sense of rotation, anti-
43
- Ctrl. KP, Dir. Cont. + KP
Commands Start and Stop via control unit, Definition
of sense of rotation via control unit or digital signals.
44
- Ctrl. Cont.+KP, Dir. Cont.+KP
Commands Start and Stop as well as definition of
sense of rotation via control unit or via digital signals.
46
- Ctrl. 3-Wire+KP, Dir. Cont.+KP
3-wire and control unit. Control of sense of rotation
and signal Start 3-Wire Ctrl 87 via digital signals or
22
ACU
Spindle Applications 11/13