8 Parameter
The parameter is available in the four data sets
Parameter
No. Description Unit Setting range
Default set-
tings
Chap-
ter
037
Start Positioning of Axle
-
Selection
75 – S6IND
5.3
382
Offset
deg
-360.0 .. 360.0
0.0
4.4
383
Voltage Constant*
mVmin
0.0 .. 6500.0
0.0
4.4.3
412
Local/Remote
- Selection
44 – Ctrl.
Cont.+KP, Dir.
Cont.+KP
3.3
417
Frequency Switch-off Limit
Hz
0.00 .. 999.99
999.99
4.4.1
469
Reference orientation
De-
grees
0.0 .. 359.9
0.0
5.3
471
Positioning Frequency
Hz
1.00 .. 50.00
50.00
5.3
472
Max positional error
De-
grees
0.1 .. 90.0
3.0
5.3.3
479
time constant positioning contr.
ms
1.00 .. 9999.99
20.00
5.3
493
Operation Mode Speed Sensor 2
-
Selection
0 - off
5.1.2.2
494
Division Marks
-
1 .. 8192
1024
5.1.2.2
624
Frequency Limit
Hz
0.00 .. 999.99
2.60
5.1.2.6
644
estimation of flux-direction -
inverted*
-
0-Off
1-On
0-Off
0
645 Operation Mode Search Run - Selection 0 - off 5.1.1.3
721
Amplification 1
-
0.00 .. 500.00
5.00
5.1.2.7
722
Integral Time 1
ms
0 .. 60000
91
5.1.2.7
723
Amplification 2
-
0.00 .. 500.00
5.00
5.1.2.7
724
Integral Time 2
ms
0 .. 60000
182
5.1.2.7
728 Current Limit A 0.0 .. 6.0 6.0 4.4.1
738
Operation Mode
Hz
0.00 .. 999.99
55.00
5.1.2.7
743
Ref. Isd Upper Limit
A
0.0 .. 6.0
0.0
5.1.1.2
744
Ref. Isd lower limit
A
-3.0 .. 3.0
0.0
5.1.1.2
760
Operation mode
-
0-off
2-Error
2-Error
5.1.2.6
766
Act. speed source
-
Selection
3-Machine
Model
5.1.2.5
800
Delay: Signal POS OK
ms
0 .. 65000
0
5.3.3
801
Delay: Error POS not OK
ms
0 .. 65000
0
5.3.3
809
Reference Profile Frequency
Hz
0.00 .. 50.00
1.00
5.3.1
810
Operation Mode Homing
-
Selection
0 - Opt
5.3.2
820
Trigger Limit BC-Test*
V
0.0 .. 100.0
7.0
5.1.3
830
Ramp Mode
-
Selection
0 – Acc./Dec.
clock-
wise/anticlockw
ise
5.4.1
831
Acc. 2/dec. 2 active
-
Selection
7 - off
5.4.2
*For PMSM only
11/13
ACU
Spindle Applications 41

Table of Contents

Other manuals for BONFIGLIOLI Active Cube

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Active Cube and is the answer not in the manual?

BONFIGLIOLI Active Cube Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelActive Cube
CategoryInverter
LanguageEnglish

Related product manuals