Interval Maintenance work Personnel
weekly Checking the functions and flow rate
— suitable measures as described in
Ä
Chapter 5.5
“Malfunctions” on page 95
— Replace damaged parts, if necessary
Operating person
monthly Checking the oil level of the machine gear unit on the oil
sight glass
— Refill, if necessary, see
Ä
Chapter 6.2.2 “Lubricant fill
level and changing the lubricants” on page 116
— If there are leaks in the gear unit / lip seal, contact
Börger customer service or send the Börger machine
for repair in accordance with
Ä
Chapter 6.3.7 “Other
repairs” on page 165
Operating person
Manufacturer
quarterly Checking the Börger machine and attachment parts for
tight fit and possible damage
— Tighten any loosened parts
—
Replace damaged parts
Operating person
Checking all safety notes, warnings and operating
instructions
— If necessary, replace damaged signs or stickers
immediately
Operating person
biannually Checking the quality of the quench fluid
— Replace quench fluid, cf.
Ä
Chapter 6.2.2 “Lubricant
fill level and changing the lubricants” on page 116
— Replace seals, if necessary, in accordance with
Ä
Chapter 6.3.4 “Replacing the mechanical seal”
on page 149
Operating person
yearly Checking the electrical system and control unit for integ-
rity and proper function.
Qualified electricians
every 2 years Changing the lubricants
— see
Ä
Chapter 6.2.2 “Lubricant fill level and changing
the lubricants” on page 116
Mechanics
every 10 years General overhaul (includes checking the carrier shafts)
— Contact Börger customer service or send the Börger
machine for a general overhaul in accordance with
Ä
Chapter 6.3.7 “Other repairs” on page 165
Manufacturer
Maintenance and Repairs