Servicing and spares | 41
6 720 ... ... (YYYY/MM)Product Name
Press the / button together with the button to enter the
“Chimney sweep mode” , the display shows the current flow
temperature and flashes the percentage heat output in the
alphanumeric display. The burner symbol will be shown in the
display.
Press the + or - buttons until the required percentage output is
displayed. Set the output to 100% initially.
The boiler will ramp up to maximum output in approximately
30 to 35 seconds.
Run the boiler at maximum output for at least 10 minutes.
Check the CO/CO
2
readings against the information in table 23.
Fig. 58
Check CO is less than 200ppm.
Set the boiler to minimum power.
The boiler will take 30 to 35 seconds to ramp down to minimum
output.
Allow the boiler to stabilise at minimum output.
Check the CO/CO
2
readings against the information in table 23.
Check that the CO is less than 200ppm.
Return the boiler to maximum and re-check the CO/CO
2
.
The boiler will take approximately 30 to 35 seconds to ramp up to
maximum output.
Allow the boiler to stabilise at maximum output.
If correct, press the button and the boiler will return to normal
operation.
Re-assemble and refit boiler case.
10.8 Setting the air/gas ratio
If the CO
2
maximum or minimum value are incorrect, the gas valve can be
adjusted as follows:
Set the boiler to maximum output
Remove the plastic dust cover [1]
Using a flat blade screwdriver adjust the maximum CO
2
setting [2]
with reference to table 23, turn clockwise to reduce or
anti-clockwise to increase the setting.
Set the boiler to minimum output
Measure the CO
2
value, it should be at the figure for minimum output
shown in table 23
It not, remove the brass dust cap [3] from the minimum adjuster
Using a 4mm Allen key to adjust the minimum setting [4] on the gas
valve until it is correct, turn clockwise to increase and anti-clockwise
to decrease the setting
Return the boiler to maximum output and check the CO
2
value
If this is correct, then return the boiler to normal operation
Remove the manometer from the flue gas sample point
Replace the flue gas sample point cap
Replace the brass dust [3] cover on the minimum adjuster [4]
Fit a new plastic dust cover [1] on the maximum adjuster [2]
Fig. 59 CO
2
adjustment
[1] Maximum adjuster plastic dust cover
[2] Maximum adjustment
[3] Minimum adjuster brass dust cover
[4] Minimum adjustment
If the CO
2
is still out of tolerance then please check the:
gas inlet pressure
gas rate
fan pressure
flue and air intake, plus any blockages in the condensate disposal
NOTICE: Minimum CO
2
The minimum CO
2
reading must be at least 0.1 lower
that the maximum CO
2
reading.
GAS TYPE
CO
2
max % setting CO
2
min % setting
G20 Natural Gas (42kW) 9.5 (+0.4/ -0.0) 9.4 (+0.4/ -0.0)
G20 Natural Gas (16 & 32kW) 9.4 (+0.4/ -0.0) 8.6 (+0.4/ -0.0)
G25 Natural gas (42kW) 7.6 (+0.4/ -0.0) 7.5 (+0.4/ -0.0)
G25 Natural Gas (16 & 32kW) 7.5 (+0.4/ -0.0) 6.9 (+0.4/ -0.0)
G31 LPG (42kW) 10.9 (+0.4/ -0.0) 10.8 (+0.4/ -0.0)
G31 LPG (16 & 32kW) 10.8 (+0.4/ -0.0) 10.5 (+0.4/ -0.0)
CO - less than 200 ppm (0.002 ratio)
Table 23 CO/CO
2
settings
6720809859-25.1Wo
The control will return to normal operation after 30
minutes or press the button.
The CO
2
should be measured 10 minutes after setting
the boiler to maximum
6720809859-62.1Wo
3
1
4
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Condens 2000F30 Regular boiler and is the answer not in the manual?

Bosch Condens 2000F30 Regular boiler Specifications

General IconGeneral
BrandBosch
ModelCondens 2000F30 Regular boiler
CategoryBoiler
LanguageEnglish

Related product manuals