Bosch D7412GV4 - Replace the Terminal Strips; Upgrade Programming to a D9412 GV4;D7412 GV4 V2.00 Control Panel

Bosch D7412GV4
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Callout Description
1 Point chart label
2 Mounting skirt hooks (2)
3 Module mounting holes (12)
4 Tamper switch mounting holes (5)
5 Skirt mounting hole (1)
6 Enclosure mounting holes (5)
7 Mounting skirt hook holes (2)
8 Back of D9412GV4/D7412GV4 Control Panel
9 Lock down tab
Notice!
If the control panel was previously mounted using the screw hole configuration, then you
must re-mount the new control panel. The D9412GV4/D7412GV4 v2.00 control panel
mounting screw hole locations do not align with the locations for older control panels.
Replace the Terminal Strips
1. Replace the removable terminal strips by pushing them straight down until they snap into
position.
Figure 3.4: Replacing the Terminal Strips
2. Connect the battery and AC power.
Upgrade Programming to a D9412GV4/D7412GV4 v2.00 Control
Panel
Notice!
You must upgrade G Series and Non-G Series control panels to GV2 programming prior to
upgrading to GV4 programming.
3.2.4
3.3
10 en | Upgrade D9412GV4/D7412GV4 Hardware and Programming Control Panel
2014.05 | 05 | F.01U.265.463 Quick Reference Guide Bosch Security Systems, Inc.