B92x/B91x Settings menu
Use the Settings menu to turn Watch mode on or off,
set the system date and time, view and change
schedules, set keypad brightness and volume, and show
the time in the keypad display.
Watch Mode
You can use Watch Mode to monitor select points with
the security system turned off. Each time points are
faulted (door or window is opened), the keypad chimes
once and shows the point text for 60 seconds. The
control panel does not generate alarms in this mode
except 24-hour alarms (fire, panic, etc.).
Use this function in residential systems to monitor
entries or exits in your home. In commercial systems it
can serve as a door chime to alert you when a customer
or delivery person enters your business.
28
28.1
Control Panels B92x/B91x Settings menu | en 181
Bosch Security Systems, Inc. 2014.04 | 05 | F.01U.287.176

Table of Contents

Other manuals for Bosch D7412GV4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D7412GV4 and is the answer not in the manual?

Bosch D7412GV4 Specifications

General IconGeneral
Communication FormatsContact ID, SIA
Operating Temperature0°C to +49°C (+32°F to +120°F)
Partitions8
Input Voltage16.5 VAC
Humidity93% non-condensing
CompatibilityBosch intrusion systems