User 1 at the office keypad
Action Area
affected
Reason
View status? All three Keypad’s scope includes
all three areas
Perform
passcode-
protected
functions?
Office User’s authority is
limited to the office
area
Result of turning the system All On? Only the office area
turns on.
User 1 at the warehouse keypad
Action Area
affected
Reason
View status? Warehouse Keypad’s scope includes
only the warehouse area
Perform
passcode-
protected
functions?
None User’s authority is
limited to the office
area, which is not within
the warehouse keypad’s
scope
Result of turning the system All On? No area turns on.