D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
.
Bosch Security Systems, Inc. | 11/05 | F01U011024B 17
Figure 8: D9210B to Door Contact Wiring
1
PWR +
7
SDIB
6
SDIA
5
COM
8
T +
10
ZN +
9
ZNCOM
2
LCKN/C
3
LCKCOM
4
LCKN/O
13
REX
12
COM
11
RTE
16
DATA 1
17
BUZZER
18
LED
15
DATA 0
14
+5.20V
1
2
3
4
1 - D9210B Access Control Module
2 - Tamper switch (normally open)
3 - Door contact (normal EOL in circuit)
4 - RTE/REX (normally open)
Table 9: Point Type and Point Response Selections
Point Type Selections
Point Response
Selections
1
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 24-Hour 6 O/C Point
Open I I I I D D I I D I I I I I T
1 Perimeter 7 D279 (O/C Non-Priority)
Armed
2
Short I I I I I I D D D I I I I I I
2 Interior 8 D279 (O/C Priority) Open T T T I I T I T
3 Interior Follower 9 Easikey
Disarmed
2
Short T T T I T I I
4 Keyswitch Maintained Open I T I T I T S T S S
5 Keyswitch Momentary
24-Hour
3
Short I I T T I T T S S S
Not
Applicable
1
Selections: D = Delayed Response, I = Instant Alarm, S = Supervisory,
T = Trouble, Blank = No Response
2
For point types 1 through 3 only.
3
For point type 0 only.