D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
.
Bosch Security Systems, Inc. | 11/05 | F01U011024B 7
3.0 Troubleshooting
3.1 Access Control Symptoms
Table 2: Access Control Symptoms
Symptom Corrective Action
Card does not open access door.
Refer to TTP1 on page 8.
Alarm occurs on access door after valid card read.
Refer to
TTP2 on page 13.
Alarm occurs when exiting an access door.
Refer to TTP3 on page 16.
SERVICE 9210 appears on the keypad.
Refer to
TTP4 on page 18.
SDI Fail 33 to 40. This error message is seen at the central station. The keypad
shows SERVICE 9210. Refer to TTP4 on page 18.
Control panel log shows “No Entry” for an alleged valid
card.
Refer to
TTP6 on page 21.
D9210B NOT READY shows on the keypad when
enrolling cards, tokens, or keyfobs.
Refer to TTP7 on page 22.
Access door unlocks when an area is disarmed.
Refer to
TTP8 on page 23.
Access door does not relock after clearing a fire alarm
and resetting the control panel.
Refer to TTP9 on page 23.