D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
52 Bosch Security Systems, Inc. | 11/05 | F01U011024B
Table 27: Value Descriptions
Figure 26: Wireless Transmitter Mode Indicator
1
Pt015: M04, 1min
Push 1 to edit
Item Variable Description
1 xxx ? D8125INV has not
received at least 30
transmissions to
determine signal strength
Bad Transmitter must be
relocated
1 - Mode Indicator
OK Good signal strength
Figure 27: Point Status Value
2 <value> Normal
2
1
Pt###= Signl xxx
<value>
Faulted
Tamper
Missing
Low Bat
Tamper, Low Bat
Faulted, Low Bat
1 - Status Value Indicator
2 - Signal Strength Indicator
Table 28: D8125INV Point Transition Reporting to
the Control Panel
If the RF Transmitter D8125INV sends to the
sends a… control panel a…
Faulted condition Shorted condition
Tamper condition Open condition
Normal condition Normal condition
Low Battery condition Low Battery condition