Bosch Security Systems, Inc. | 11/05 | F01U011024B 61
Table 33: Extra Point Log
On-Board D8128C/D D8125/D9127 D8125MUX D8125INV D9210B
Table 34: Point Type and Point Response Selections
Point Type Selections
Point Response
Selections
1
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 24-Hour 6 O/C Point
Open I I I I D D I I D I I I I I T
1 Perimeter 7 D279 (O/C Non-Priority)
Armed
2
Short I I I I I I D D D I I I I I I
2 Interior 8 D279 (O/C Priority) Open T T T I I T I T
3 Interior Follower 9 Easikey
Disarmed
2
Short T T T I T I I
4 Keyswitch Maintained Open I T I T I T S T S S
5 Keyswitch Momentary
24-Hour
3
Short I I T T I T T S S S
Not
Applicable
1
Selections: D = Delayed Response, I = Instant Alarm, S = Supervisory,
T = Trouble, Blank = No Response
2
For point types 1 through 3 only.
3
For point type 0 only.
Figure 30: Point Expansion Technology Powered from Auxiliary Power Supply
28
27
26
25
24
23
GND
AUX
IN
OUT
Point Expansion
Technology
Control Panel
12 V Auxiliary
Power Supply
- +

Table of Contents