61
Error messages
Display Error source Measure
540 Overheating of the drive unit
- 1) Switch the e-bike off�
- 2) Let the motor cool off�
- 3) Select a low riding mode�
550 USB consumer Disconnect the external device from the USB port and restart the e-bike.
580 Software version Restart the e-bike
591 Authentication Switch the e-bike off� Remove the rechargeable battery and insert it again� Re
-
start the e-bike�
592 Incompatible components Insert compatible display.
593 Configuration Restart the e-bike�
595, 596 Communication Check the cable connections and contacts (visual check)� Restart the e-bike�
602 Rechargeable battery or charging error
of the rechargeable battery
- 1) Restart the e-bike�
or
- 1) Disconnect the charger from the rechargeable battery
- 2) Restart the e-bike�
- 3) Connect the charger to the rechargeable battery
603 Rechargeable battery Restart the e-bike�
605 Temperature of the rechargeable battery
or charging error of the rechargeable
battery
Let the rechargeable battery reach the operating temperature�
or
Disconnect the charger from the rechargeable battery and let the rechargeable
battery and charger reach the operating temperature�
606 Rechargeable battery connection Check the cable connections and contacts�
610 Rechargeable battery voltage error Restart the e-bike�
620 Charger Replace the charger� Only use an approved charger
640 Rechargeable battery Restart the e-bike�