ICP-CC408 | Installation Guide | 24.0 Programming Sheets EN | 100
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
User Code Priority Levels
Priority Description
0 Arm/disarm
1 Arm only
2 Arm/disarm and Open/Close Reports
3 Arm only and Close Report
4 Arm/disarm and code to isolate
6 Arm/disarm, code to isolate, and
Open/Close Reports
8 Arm/disarm and Master Code functions
10
Arm/disarm, Master Code functions, and
Open/Close Reports
12 Arm/disarm, Master Code functions, and
code to isolate
14
Arm/disarm, Master Code functions, code
to isolate, and Open/Close Reports
Day Alarm Zones
Location
265 Refer to page 56
Default
0
1 Zone 1
2 Zone 2
4 Zone 3
8 Zone 4
EOL Resistor Value
Location
266 Refer to page 56
0 No EOL resistor
1 1K (brown, black, red)
2 1K5 (brown, green, red)
3 2K2 (red, red, red)
4 3K3 (orange, orange, black, brown) 1%
5 3K9 (orange, white, red)
6 4K7 (yellow, white, red)
7 5K6 (green, blue, red)
8 6K8 (blue, grey, black, brown) 1%
9 10K (brown, black, orange)
10 12K (brown, red, orange)
11 22K (red, red, orange)
12 Reserved
13 Reserved
14 Reserved
15
Split EOL (3K3/6K8) 1% resistors required.
Eight programmable zones.
Zones
Location
267 to 322 Refer to page 58
Zone 1
Locations 267 to 273
Default
2 0 0 1 14 1 1
Zone 2
Locations 274 to 280
Default
1 0 0 1 14 1 1
Zone 3
Locations 281 to 287
Default
1 0 0 1 14 1 1
Zone 4
Locations 288 to 294
Default
1 0 0 1 14 1 1
Zone 5
Locations 295 to 301
Default
0 0 0 1 14 1 1
Zone 6
Locations 302 to 308
Default
0 0 0 1 14 1 1
Zone 7
Locations 309 to 315
Default
0 0 0 1 12 1 1
Zone 8
Locations 316 to 322
Default
9 0 0 1 12 1 1
Each zone contains seven locations. The first three
locations determine how the zone operates:
Zone Type Zone Pulse
Count
Zone Pulse
Count Time
The next two locations contain zone options:
Zone Options 1 Zone Options 2
The last two locations contain reporting information:
Report Code Dialer Options
Zone Types
These are the zone types available:
Zone Type Description
0 Instant
1 Handover
2 Delay-1
3 Delay-2
4 Reserved
5 Reserved
6 24-Hour Medical
7 24-Hour Panic
8 24-Hour Holdup
9 24-Hour Tamper
10 Reserved
11 Keyswitch
12 24-Hour Burglary
13 24-Hour Fire
14 Chime only
15 Zone not used