EasyManua.ls Logo

Bosch ICP-SOL2-P - 4 Operation with TEXT LCD Codepad; 4.1 Text Menu Overview

Bosch ICP-SOL2-P
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bosch Security Systems, Inc. Quick Reference Guide 2014.06 | 02 | F01U298027
10 en | Operating Commands Control Panel
Programming Option Bits
Use option bits to program any combination of the four different options in one location by
adding the options together. Programming a zero disables all four options.
Example
If at Location 0177 you only want options 1, 2, and 4, add the numbers together and the total
is the number to be programmed. The number to be programmed is 7 (1 + 2 + 4 = 7).
Option Description
1 Dialer reporting functions allowed
2 Remote arming using Telephone allowed
4 Answering machine bypass only when armed
8 Use bell 103 for FSK format (Disabled = CCITT V21)
Table 2.3: Programming Option Bits
Installer's programming commands
Installer Programming Commands, displayed in below table can only be used when you enter
Installer’s Programming Mode. Enter the command followed by the [#] key.
Command Description
958 Exit from Installer’s Programming Mode without saving changes
959 Test IUI-SOL-ADAPTER
960 Exit from Installer’s Programming Mode with saving changes and panel
reset
961 Reset the control panel to factory defaults
962 Copy the control panel memory to IUI-SOL-ADAPTER
963 Copy IUI-SOL-ADAPTER data to the control panel memory
965 Set up domestic dialing format
966 Enable/disable the automatic stepping of locations during programming
999 Display the software version number or control panel type
Table 2.4: Installer’s Programming Commands