Speaker Beep Volume
Item Location Option Default New
Speaker Beep Volume 0491 0 = No Beeps
15 = Loudest Beeps
13
Options Programming
System Options 1
Item Location Option Default New
System Options 1 0492 1 = Bosch Security Systems smart lockout
allowed
2 = Horn speaker monitor
4 = Strobe indication for radio arm/disarm
8 = Assign button 4 on transmitter to operate
STAY Mode 1
1
System Options 2
Item Location Option Default New
System Options 2 0493 1 = Codepad panic to be silent
2 = Codepad fire to be silent
4 = Codepad medical to be silent
8 = Access denied (code retries) to be silent
0
System Options 3
Item Location Option Default New
System Options 3 0494 1 = AC fail after 1 hr. (Disabled = after 2 min.)
2 = Ignore AC fail
4 = Pulse count handover allowed
8 = Handover delay to be sequential
8
System Options 4
Item Location Option Default New
System Options 4 0495 1 = Panel to power up disarmed (if power
reset)
2 = Arm/disarm tracking on power up
4 = Reserved
8 = Reserved
2