Control Panel Operating Commands | en 15
Bosch Security Systems, Inc. Quick Reference Guide 2014.06 | 02 | F01U298027
Set STAY Mode 2 Zones
1. Enter the Installer Code or Master Code, followed by [4] and the [#] key.
2. Enter the Zone Number you want the system to automatically isolate, followed by the [*]
key. Repeat if more than one zone must be automatically isolated when armed in STAY
Mode 2.
3. Press the [#] key to exit.
Report Monitor Mode (Toggle On/Off)
1. Enter the Installer Code, followed by [6] and the [#] key.
2. Press and hold the [9] key until two beeps are heard to send a test report.
Zone Indicator Dialing Event
1 Telephone Line Seized
2 Dialing Telephone Number / Network Connect
3 Handshake Received
4 Data Being Sent
5 Kiss-Off Received
None Released Telephone Line / Idle
Table 3.2: Report Monitor Mode
Notice!
You must exit from Report Monitor Mode to resume normal operations.
Walk Test Mode
1. Enter the Installer Code or Master Code, followed by [7] and the [#] key.
2. Test each zone as required.
3. Press the [#] key to exit.
Event Memory Recall
Enter the Installer Code or Master Code, followed by [8] and the [#] key.
The last 256 events are displayed in reverse order (for example, most recent to least recent).
3.7
3.8
3.9
3.10