Authority Levels Description
6 Arm/Disarm and Arm/Disarm Reports and Code Required to Isolate
8 Master Code and Arm/Disarm
10 Master Code and Arm/Disarm and Arm/Disarm Reports
12 Master Code and Arm/Disarm and Code Required to Isolate
14 Master Code and Arm/Disarm and Code Required to Isolate and Arm/Disarm
Reports
Table 4.1: Authority Levels
Day Alarm Zones
Item Location Option Default New
Day Alarm Zones 0265 1 = Zone 1
2 = Zone 2
4 = Zone 3
8 = Zone 4
0
EOL Resistor Value
Item Location Option Default New
EOL Resistor
Value
0266 0 = No EOL
1 = 1k
2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6
8 = 6k8
9 = 10k
10 = 12k
11 = 22k
12 = Reserved
13 = Reserved
14 = Split EOL (3k3/6k8
with tamper 1k)
15 = Split EOL (3k3/6k8)
15
Zone Programming
Item Location Default New Item Location Default New
Zone #01 Zone #09
Zone Type 0267 2 Zone Type 0323 15
Zone Pulse Count 0268 0 Zone Pulse Count 0324 0
Zone Pulse Count Time 0269 0 Zone Pulse Count Time 0325 0
Zone Options 1 0270 1 Zone Options 1 0326 1
Zone Options 2 0271 14 Zone Options 2 0327 14
Reserved 0272 Reserved 0328
Dialer Options 0273 1
11
Dialer Options 0329 1
Zone #02 Zone #10
4.4
4.5
4.6