Item Location Default New Item Location Default New
Zone Pulse Count 0303 0 Zone Pulse Count 0359 0
Zone Pulse Count Time 0304 0 Zone Pulse Count Time 0360 0
Zone Options 1 0305 1 Zone Options 1 0361 1
Zone Options 2 0306 14 Zone Options 2 0362 14
Reserved 0307 Reserved 0363
Dialer Options 0308 1
1
11
1
Dialer Options 0364 1
Zone #07 Zone #15
Zone Type 0309 0 Zone Type 0365 15
Zone Pulse Count 0310 0 Zone Pulse Count 0366 0
Zone Pulse Count Time 0311 0 Zone Pulse Count Time 0367 0
Zone Options 1 0312 1 Zone Options 1 0368 1
Zone Options 2 0313 14 Zone Options 2 0369 14
Reserved 0314 Reserved 0370
Dialer Options 0315 1 Dialer Options 0371 1
Zone #08 Zone #16
Zone Type 0316 9 Zone Type 0372 15
Zone Pulse Count 0317 0 Zone Pulse Count 0373 0
Zone Pulse Count Time 0318 0 Zone Pulse Count Time 0374 0
Zone Options 1 0319 1 Zone Options 1 0375 1
Zone Options 2 0320 12 Zone Options 2 0376 14
Reserved 0321 Reserved 0377
Dialer Options 0322 1
11
Dialer Options 0378 1
For zone item options, refer to below Zone Item Options.
Item Option
Zone Type 0 = Instant
1 = Handover
2 = Delay-1
3 = Delay-2
4 = Reserved
5 = Reserved
6 = 24-Hour Medical
7 = 24-Hour Panic
8 = 24-Hour Hold-up
9 = 24-Hour Tamper
10 = Reserved
11 = Keyswitch
12 = 24-Hour Burglary
13 = 24-Hour Fire
14 = Chime Only
15 = Not used
Zone Pulse Count Use the pulse count to program how many pulses (0 to 15) need to
be registered within the pulse count time to activate an alarm.
Zone Pulse Count Time 20 ms Loop Response Time 150 ms Loop Response Time
2 en | Programming Parameters Control Panel
2014.06 | 02 | F01U298027 Quick Reference Guide Bosch Security Systems, Inc.