12.4.4 Poor Dehumidi cation
LED display output: No fault code displayed
Description: System is running, but not dehumidifying the space to customer’s expectation
Possible causes:
Unit improperly sized
Duct work design error
Unit improperly charged
Improper indoor fan speed
Table 50
Procedure:
Figure 37
Refer to IOM and follow
local codes
No
Yes
Was ductwork
installed properly?
Confirm sizing via load
calculation
Is the unit sized
correctly for the
application?
Yes
No
Refer to IOM
No
Yes
Is the system
properly charged?
Yes
Is there still poor
dehumidification?
No service required
No
Change SW4-4 to on
position on outdoor board.
Set indoor fan to lower
speed using SW6-1, SW6-2
on indoor board
Yes
Is there still poor
dehumidification?
No service required
No
Disconnect Y2. Only Y1
should be connected.
Yes
Is there still poor
dehumidification?
No service required
No
Consider putting a third
party dehumidifier in
conditioned space

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch IDS 2.0 and is the answer not in the manual?

Bosch IDS 2.0 Specifications

General IconGeneral
RefrigerantR-410A
StagesVariable
Voltage208/230 V
System TypeAir Source Heat Pump
Compressor TypeInverter-driven
Sound LevelAs low as 56 dB
Heating CapacityVaries by model
Cooling CapacityVaries by model
Noise Level45 dB to 60 dB
Operating Temperature Range (Heating)-20°C to 35°C
Dimensions (Outdoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
Seasonal Coefficient of Performance (SCOP)Not Available

Related product manuals