28 | KTS 530 / 540 / 570 (KTS 5 Series) | Decommissioning
6. Decommissioning
6.1 Temporary shutdown
In the event of lengthy periods of non-use:
6.2 Change of location
¶ If the KTS 530 / 540 / 570 (KTS 5 Series) is passed on,
all the documentation included in the scope of delivery
must be handed over together with the unit.
¶ The KTS 530 / 540 / 570 (KTS 5 Series) is only ever
to be transported in the original or equivalent pack-
aging.
¶ Unplug the electrical connection.
¶ Heed the notes on initial commissioning.
¶ Disconnect the KTS 530 / 540 / 570 (KTS 5 Series)
from the mains.
6.3 Disposal and scrapping
1. Disconnect the KTS 530 / 540 / 570 (KTS 5 Series)
from the mains and detach the power cord.
2. Dismantle the KTS 530 / 540 / 570 (KTS 5 Series)
and sort out and dispose of the different materials in
accordance with the applicable regulations.
6.4 Disposal
This KTS 530 / 540 / 570 (KTS 5 Series) is
subject to European guidelines 2012/19/EU
(WEEE).
Old electrical and electronic devices, includ-
ingcables and accessories or batteries must
be disposed of separate to household waste.
¶ Please use the return and collection sys-
tems in place for disposal in your area.
¶ Damage to the environment and
hazards to personal health are pre-
vented by properly disposing of
KTS 530 / 540 / 570 (KTS 5 Series).
7. Technical data
7.1 General data
Property Value/Range
Operating voltage 7 VDC — 30 VDC
Power consumption through vehicle bat-
tery or power supply
approx. 6 Watt
Dimensions (L x W x H) 170 x 120 x 40 mm
Weight (without connecting cables) 325 g
Degree of protection IP 20
Operating temperature 5 °C – 40 °C
41 °F – 104 °F
Storage Temperature -25 °C – 60 °C
-13 °F – 140 °F
Relative operating humidity 90 % non-
condensing
7.2 Interface protocols
The following interfaces with respective protocols are
supported for controller diagnosis in conformance with
ISO 15031:
R ISO 9141-2 (Communications lines K and L)
R SAE J1850VPW and SAE J1850PWM
(Communication lines BUS+ and BUS-)
R CAN ISO 11898 ISO 15765-4 (OBD)
(Communication lines CAN-H and CAN-L)
R CAN Single Wire
R CAN Low Speed
7.3 Multimeter specifications
Measuring channel 1 (CH1) zero potential
Measuring channel 2 (CH2) potential based
Input resistance > 900 kOhm.
7.3.1 DC measurement (CH1 and CH2)
! Use measuring leads for measurements smaller than
60 VDC, 30 VAC or 42 VACpeak only.
Property Value/Range
Measurement range 200 mV — 60 V
Precision CH1 ±0.75 % of measurement value,
additional ±0.25 % of measurement range
Precision CH2 ±2 % of measurement value,
additional ±0.5 % of measurement range
Resolution 100 µV — 100 mV
(depending on measuring range)