Network
Unit name
Default: clear
Enter a name for the device. This name will be displayed in the title of the web browser
application page.
IP address
Default: 0.0.0.0
You can enter the 4 values of the announced IP address to create a static IP address, or ask
your system administrator for a valid IP address and enter it here. Or you can enter e.g.
192.168.0.12 for an internal LAN.
Subnet mask
Default: 0.0.0.0
You can also enter the 4 values of the desired static IP address, or enter 255.255.255.0 for a C
class network (standard).
Default gateway
Default: 0.0.0.0 (no gateway)
You can also enter the 4 values of the desired Gateway IP address, or 192.168.0.1 for a
Gateway in a LAN.
Notice!
The Gateway has to be set only when connecting to other devices over a WAN through a
router.
Type of Service / DSCP
Default value: 0Differentiated Service Code Point (DSCP) is used for audio streaming. This
supersedes the IP4 Type of Service (ToS) value and uses the same byte. Valid values are 0 -
63. Check for DSCP services available in your network to set this value. The recommended
DSCP for voice traffic is the value 46 for Expedited Forwarding (EF).
Use SonicIP
Default: Yes
The device will announce its IP address over the Audio Outputs 1 and 2. If you select NO, then
the device will not announce its IP address. This way start up is faster.
Submit / Cancel button
Submit saves the set values, restarts the device and returns back to the last screen. Cancel
restores the last submitted values.
6.2.1
18 en | Configuration IP Audio Interface
2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.