EasyManua.ls Logo

Bosch PRS-1AIP1 - Control Output Status; Audio Status Indicators; Codec and Application Mode; Power, Fault, and Temperature Status

Bosch PRS-1AIP1
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control Outputs (1..8)
Visual indication of the Control Output status.
– Grey box: idle
– Green box: active
Audio
Visual indication of the Audio In/Out status.
Pilot tone (Audio Input 2 only).
– Grey box: no pilot tone configured
– Green box: pilot tone detected
– Yellow box: fault (pilot tone configured but not detected)
Microphone supervision (Audio Input 1 only)
Dyn.: status for dynamic microphone
Cond.: status for condenser microphone
– Grey box: supervision disabled
– Green box: microphone detected
– Yellow box: fault (microphone disconnected or shorted)
Audio In/Out 1 and 2
The audio peak level at Audio In 1/2 and Audio Out 1/2 in dB below maximum level.
Codec
Visual text indication of the data streaming status.
Audio Coding
– ENCODING: audio from an Audio Input is transmitted to the network
– DECODING: audio is received from the network and available on the Audio Output(s)
– FULL DUPLEX: audio from the Audio Input(s) is transmitted to the network and, at the
same time, audio is received from the network and available on the Audio Output(s)
– DEVICE ERROR: indicates an error condition which is given in the CONFIG VIEW page
Application Mode
– IDLE: no data stream received or send
– TRANSMIT: data stream is sent to the network
– RECEIVE: data stream is received from the network
– TRANSMIT + RECEIVE: data stream is sent to the network and received from the network
– REBROADCAST: data stream is received from the network and retransmitted to a defined
group of receivers (Partners)
Power, Fault & Temperature
Visual indication of the power, fault and temperature status.
Main PWR (values in Volt)
– Green box: main power supply (17) OK
– Yellow box: main power supply (17) fault
Back-up PWR (values in Volt):
– Green box: back-up power supply (16) OK
– Yellow box: back-up power supply (16) fault
Fault Relay
– Green box: no fault detected
– Yellow box: fault detected
Internal Temp. (°C)
– Green box: temperature is below the set limit
– Yellow box: temperature exceeds the set limit
7.1.2
7.1.3
7.1.4
7.1.5
40 en | Operation IP Audio Interface
2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.