Control Outputs (1..8)
Visual indication of the Control Output status.
Grey box: idle
Green box: active
Audio
Visual indication of the Audio In/Out status.
Pilot tone (Audio Input 2 only).
Grey box: no pilot tone configured
Green box: pilot tone detected
Yellow box: fault (pilot tone configured but not detected)
Microphone supervision (Audio Input 1 only)
Dyn.: status for dynamic microphone
Cond.: status for condenser microphone
Grey box: supervision disabled
Green box: microphone detected
Yellow box: fault (microphone disconnected or shorted)
Audio In/Out 1 and 2
The audio peak level at Audio In 1/2 and Audio Out 1/2 in dB below maximum level.
Codec
Visual text indication of the data streaming status.
Audio Coding
ENCODING: audio from an Audio Input is transmitted to the network
DECODING: audio is received from the network and available on the Audio Output(s)
FULL DUPLEX: audio from the Audio Input(s) is transmitted to the network and, at the
same time, audio is received from the network and available on the Audio Output(s)
DEVICE ERROR: indicates an error condition which is given in the CONFIG VIEW page
Application Mode
IDLE: no data stream received or send
TRANSMIT: data stream is sent to the network
RECEIVE: data stream is received from the network
TRANSMIT + RECEIVE: data stream is sent to the network and received from the network
REBROADCAST: data stream is received from the network and retransmitted to a defined
group of receivers (Partners)
Power, Fault & Temperature
Visual indication of the power, fault and temperature status.
Main PWR (values in Volt)
Green box: main power supply (17) OK
Yellow box: main power supply (17) fault
Back-up PWR (values in Volt):
Green box: back-up power supply (16) OK
Yellow box: back-up power supply (16) fault
Fault Relay
Green box: no fault detected
Yellow box: fault detected
Internal Temp. (°C)
Green box: temperature is below the set limit
Yellow box: temperature exceeds the set limit