CI (Control Input)
Enter the number of the Control Input (1 - 8) of the receiver that will accept the audio stream
from this partner. If the transmitting partner is streaming (always) to this receiver, this
selection determines the accepted audio stream unless it is overruled by a higher priority
stream. The default 0 means that a stream from this partner is not selected by a Control Input.
Full duplex connections are considered to be permanent one-to-one connections for which
Control Input selections are ignored.
Blk Inc (Block Incoming)
Default: unchecked
Check the check box to block the incoming data from the respective partner. Priority and
Control Input settings are ignored. The option to block individual partners is only available if
the unknown partner is already blocked.
Spr Ply (Suppress Play)
Default: unchecked
Check the check box to suppress local playback of audio. This mode is used when re-
broadcasting the incoming stream to other devices.
Re brd (Re-broadcast)
Default: Unchecked
Check the check box to allow for re-broadcasting to this IP address.
Sup vse (Supervise)
Check the checkbox to supervise the connection between the receiver and this partner. Even
in case no audio stream is present the connection will be polled on a regular basis using an
ICMP message type 1 (ping). The replies will be counted and if 3 consecutive pings are not
answered the partner device will be assumed to be off-line and the fault relay is activated.
Pings may also be lost due to network congestion but if the network connection is so bad that
3 consecutive replies are lost this condition should also be investigated. If all supervised
devices come back on line then the fault relay will be cleared.
IP address
Default: 0.0.0.0
You can enter the IP address of the partner device here.
Port
Default: 3030
You can enter the port number of the partner device here, between 0 and 65535.
Submit / Cancel button
Submit saves the set values, restarts the device and returns back to the last screen. Cancel
restores the last submitted values.
IP Audio Interface
Configuration | en 21
Bosch Security Systems B.V. Operating Manual 2013.03 | V2.0 |