Supervision Sensor Mapping
Default: None
In the Supervision Sensor Mapping table you can select what actions should be taken if one of
the faults occur that are in the table.
Options are: None, Local, Remote, Local and Remote.
None means that no action is taken when this fault occurs, except for indication on the
Status page, see Status page, page 39.
Local means that the fault is only indicated on the device itself.
Remote means that the fault is sent to and indicated on the partner devices.
Local and Remote means that the fault is indicated on both the device itself and the
partner devices.
Faults that can be mapped are:
Control Inputs 1..8 fault. This fault can occur if the connections to one or more of the Control
Inputs are interrupted or shorted. Supervision should be enabled to detect this type fault, see
Control Input Mapping Table, page 29.
Temperature fault. This fault occurs if the set temperature is exceeded, see Supervision, page
27.
Backup Power fault. This fault occurs when the backup voltage drops below the set value, see
Supervision, page 27.
Main Power fault. This fault occurs when the main power supply becomes disconnected.
Condenser Microphone fault. This fault occurs when the connected condenser microphone
becomes disconnected or fails. Supervision for the microphone input should be enabled, see
Audio Settings, page 24.
Dynamic Microphone fault. This fault occurs when the connected dynamic microphone
becomes disconnected or fails. Supervision for the microphone input should be enabled, see
Audio Settings, page 24.
Pilot Tone fault. This fault occurs when no pilot tone is detected at Audio Input 2. Pilot Tone
supervision should be enabled, see Audio Settings, page 24.
Stream Loss fault. This fault occurs when the incoming data stream is lost, e.g. because the
device became disconnected from the switch. A Stream Loss fault can only be Local, as there
is no way to inform the partner devices, because of the disconnection.
Submit / Cancel button
Submit saves the set values, restarts the device and returns back to the last screen. Cancel
restores the last submitted values.
28
en | Configuration IP Audio Interface
2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.