UL ratings and dimensions (XMS*-W0006 … 0036)
Description Symbol Unit
XMS*-
W0006
XMS*-
W0010
XMS*-
W0016
XMS*-
W0023
XMS*-
W0030
XMS*-
W0036
Listing in accordance with UL
standard
UL 61800-5-1
Listing in accordance with CSA
standard
C22.2 No. 274-17
UL‑Files E134201
Pollution degree 2
Ambient temperature range with
nominal data
T
amax
°C 40
Mass m kg 2.8
Device height
1)
H mm 309
Device depth
2)
T mm 196.5
Device width
3)
B mm 50
Minimum distance on the top of
the device
4)
d
top
mm 80
Minimum distance on the bottom
of the device
5)
d
bot
mm 80
Horizontal spacing at the device
6)
d
hor
mm
0 (for devices of the ctrlX DRIVE product group in the DC bus
group (central supply))
1.5 (for devices of the ctrlX DRIVE product group outside of the
DC bus group (individual supply))
10 (for everything else (control cabinet wall, other devices, etc.))
Rated control voltage input
7)
U
N3
V 24
Rated control current input
8)
I
N3
A 3.3
Short circuit current rating SCCR A rms 42000
Rated input voltage, power
9)
U
LN_nom
V DC 254 ... 750
Rated input current
I
LN
A DC 2.4 DC 4.1 DC 6.5 DC 9.4 DC 14.6 DC 22
Field wiring material (material;
conductor temperature; class)
Cu; 75 °C; 1
Output voltage
U
out
V AC 0 … 500
Output current
I
out
A AC 2 AC 3.3 AC 5.3 AC 7.7 AC 12 AC 18
Output frequency range
11)
f
out
Hz 0 ... 1600
1) 2) 3) Housing dimensions
4) 5) 6) See fig. "Air intake and air outlet at device"
7) Comply with supply voltage for motor holding brake;
The following power supply unit has to be used in the scope of
CSA/UL: ● UL508-certified ● output voltage: DC 24V ● output
current: ≤ 31 A; for power supply units with output current >
31 A: install fuses in accordance with UL248
8) See information on "Rated power consumption control voltage
input at U
N3
"
ctrlX DRIVE Drive Controllers, Supply Units 11/43
Ratings and dimensions
R911392530_Edition 02 Bosch Rexroth AG