32/69
Bosch
Rexroth
AG
Instructions for Use
HCS02.1
E-W0012, -W0028
View
,.---, ,.---,
,.---,
,.---,
u L2 L3
@
h----1
ti
tj
1---1
Ll---\
~
DA
000179v01 _nn.FH11
Screw
connection
at
connector
Tightening
torque
Connection
cross
section
Stranded wire
NOTICE
DOK-INDRV*-HCS02*UL
***-1803-EN-P
Rexroth lndraDrive Drive Controllers
Power
Sections HCS02
Damage
to
the
device!
Provide strain relief for the terminal connectors of the device
in
the control cab-
inet or use the optionally available connection accessory HAS02.
ldentifica-
Function
3-phase
operation
Function
1-phase
operation
tion
L1
Connection to supply mains (L 1)
L2 Connection to
supply mains
Connection to
neutral conduc-
(L2)
tor
supply mains
L3 Connection to
supply mains
n.c.
(L3)
@
Connection
of
equipment grounding conductor
of
drive con-
troller
Unit
Min.
Max.
Nm 0,5
0,6
mm
2
1,5
4
AWG 16
10
Occurring current load and minimum required
See
technical data
of
device used
(ILN
and A
LN
)
connection cross section
Occurring
voltage load
See technical
data
of
device used
(ULN)
Fig.S-4: Function, Pin Assignment, Properties
HCS02.1
E-W0054, -W0070
View
ldentifica-
Function
3-phase
operation
Function
1-phase
operation
tion
(only HCS02.1 E)
,.---, ,.---,
,.---, ,.---,
L1
Connection to supply mains (L
1)
u L2
L3
@
L2 Connection to supply mains Connection to neutral conduc-
11---i
ti
tj
t-----1
(L2) tor supply mains
Ll--\
~
L3 Connection to supply mains n.c.
(L3)
DA000179v01 _nn.FH11
@
Connection
of
equipment grounding conductor
of
drive con-
troller
Screw
connection
at
connector
Unit
Min.
Max.
Tightening
torque
Nm
1,5 1,7
Connection
cross
section
mm
2
1,5
16
Stranded wire
AWG 16 6