DOK-INDRV*-HCS02*UL
-*-1803-EN-P
Bosch
Rexroth
AG
45/69
Rexroth
lndraDrive
Drive
Controllers
Power
Sections
HCS02
5.3
5.3.1
Installation
Instructions for Use
The
accessory
HAS02
contains all parts required for effective shield connection
of
the motor cable (see index entry "Accessories").
General
Information
on
How
to
Install
the
Drive
Controller
-
!ft'IJWMG-
Lethal
electric
shock
caused
by
live
parts
with
more
than
50
V!
Before working
on
live parts: De-energize the installation and secure the power
switch against unintentional or unauthorized re-energization.
Wait at least
30
minutes
after switching off the supply voltages to allow dis-
charging. To shorten the waiting time until voltage has fallen below 50
V,
you
can use a discharging device (see chapter
"Appendix").
Check whether voltages have fallen below 50 V before touching live parts!
Damage can
be
caused to the drive controller or circuit boards if electrostatic
charging present
in
people and/or tools
is
discharged across them. For this
reason, please observe the
following information:
NOTICE
Electrostatic
charges
can
cause
damage
to
electronic
components
and
interfere
with
their
operational
safety!
Exposed conductive parts coming into contact with components and circuit
boards must
be
discharged by means of grounding. Otherwise errors may occur
when
controlling motors and moving elements.
Such exposed conductive parts include:
• The copper bit when solderi
ng
• The human body (ground connection by touching a conductive, grounded
object)
• Parts and tools (place them
on
a conductive support)
Endangered components may only be stored or dispatched
in
conductive pack-
aging.
~
Rexroth connection diagrams are only to
be
used for producing in-
stallation circuit diagrams! The machine manufacturer's installation
circuit diagrams must
be
used for wiring the installation!
• Lay signal lines separately from the load resistance lines because of the
occurrence
of
interference.
• Transmit analog signals
(e
.
g.
command values, actual values) via shiel-
ded lines.
•
Do
not connect mains,
DC
bus or power cores to low voltages or allow
them to come into contact with these.
• When carrying out a high voltage test or
an
applied-overvoltage withstand
test
on
the machine's electrical equipment,
disc;;onnect
all connections to
the devices. This protects the electronic components
(allowed
in
accord-
ance with
EN
60204-1
).
Duri
ng
their routine testing, Rexroth drive com-
ponents are tested for high voltage (in accordance with
EN