38/69
Bosch
Rexroth
AG
Instructions for Use
DOK-INDRV*-HCS02*UL
***-1603-EN-P
Rexroth lndraDrive Drive Controllers Power Sections HCS02
The external braking resistor must
be
parameterized
via the firm-
ware to protect the drive
controller and the braking resistor against
overload.
See also Parameter Description of the firmware used:
"P-0-0860, Converter configuration"
and
"P-0-0858, Data of external braking resistor"
The drive
controller monitors the operating data of the external
braking resistor against the data
in
"P-0-0858, Data of external
braking resistor". Select braking resistors with a performance that
corresponds to the parameterized
values or more powerful braking
resistors.
X9,
External
Braking
Resistor
HCS02.1
E-W0054
and
-W0070
Function,
Pin
Assignment
X9
is
used
to
connect
an
external braking resistor which
is
controlled via the
internal switch.
View
00
DA0001
78v01
nn.F
H1
'
Screw
terminal
(connector)
Connection line
Stranded wire
Tightening torque
Current
load
Voltage load
Short
circuit protection
~
For HCS02 devices, the connection X9
is
contained
in
all designs,
except for
-W0012 and -W0028.
Con
nee-
Signal
name
Function
tion
1 n.
s.
Connection braking resistor
2 n.s.
Connection braking resistor
Unit
Min.
Max.
mm
2
2,5
4
AWG
14
10
Nm 1,5
1,7
A Peak
value: 30
R.m.s. value: 15
v
n.s.
To be ensured by means
of
appropriate fusing elements
in
the
mains connection at X3
n.s. Not specified
Fig.5-11: Function, Pin Assignment
Notes
on
Installation
Maximum allowed line length to external braking resistor: 5 m
Twist
unshielded lines.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com