EasyManua.ls Logo

Bosch Rexroth lndraDrive HCS02.1E-W0012 03 Series - Ground Connections

Bosch Rexroth lndraDrive HCS02.1E-W0012 03 Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56/69
Bosch
Rexroth
AG
DOK-INDRV*-HCS02*UL
***-1803-EN-P
Rexroth lndraDrive Drive Controllers Power Sections
HCS02
EMC Measures for Design and Installation
Converter
-
Routing
the
Motor
Power
Cables
With
cable
duct
Without
cable
duct
B
c
1
2
3
4
5
-
----
- - -,,-
-----
--
-----
---
:8
--,-----
---(:-
c
,:
I
I;
I
I
I I 1 I
~
h
-----
·
:
!__t;
:r
~
:r
~
:r
~
r ij
7'"
]o
I ,
.J-
---
-
--
.
~
-~
-
~~-=-
-
~
-~-
-
~-~
-=-
-=-=-~
j
le
'
'
'
'
'
'
·-
--
-
--
----
--
--
--
-----
--
----
--
---------- -------
--
---
--
DE000021
V02
nn.
lh
ll
Area B
Area
C
B
c
Shield connection of motor power cable
via
1
clips
at
least
at
one
point; alternativel
y,
at
the
2
device or
on
mounting plate at control cabinet
Cab
le duct for mains connection lines
Cable duct for motor power cables
Para
l
lel
routing of mains connection lines
and
3
motor power cables over a maximum of
300
4
mm
Distance of
at
least
100
mm
or separated
by
a grounded distance plate
5
Area
B
Area
C
OE
000020V02 nn
.fh
l l
Cable duct for mains connection lines
Shield connection of motor power
cab
le
via
clips
at
least
at
one
po
i
nt;
alternatively,
at
the
device or
on
mounting plate
at
control cabinet
Control cabinet outl
et
of
moto
r power cables
Parallel routing of mains connection lines
and
motor power cables over a
max
i
mum
of
300
mm
Fig.6-2:
Routing
of
Motor
Power
Cables With Cable
Duct
Distance of
at
least
100
mm
or separated
by
a grounded distance plate
Fig.6-4:
6.3
Ground
Connections
Fig.6-3:
Routing
of
Motor
Power
Cables Without Cable
Duct
Routing
of
Cables for Converter
Housing
and
Mounting
Plate
By means
of
appropriate ground connections,
it
is possible to avoid the emis-
sion
of
interference, because interference is discharged to ground on the
shortest possible
way
.
Ground connections of the
metal housings
of
EMC-critical components (such
as filters, devices
of
the drive system, connection points
of
the cable shields,
devices with microprocessor and switching power supply units) have to be
well
contacted over a large surface area. This also applies to all
screw
connections
between mounting
plate and control cabinet wall and to the mounting
of
a
ground bus to the mounting plate.
The best solution is to use a zinc-coated mounting plate. Compared to a
lac-
quered plate, the connections in this case have a good long-time stability.
Connection
Elements
For
lacquered mounting plates, always use screw connections with tooth lock
washers and zinc-coated, tinned screws as connection elements. At the con-
nection points, remove the lacquer so that there is safe electrical contact over
a large surface area.
You achieve contact over a large surface area by means
of
bare connection surfaces
or
several connection screws. For screw connec-
tions, you can establish the contact to lacquered surfaces by using tooth
lock
washers.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Related product manuals